Questions & Answers
Q8 THE MOTOR DOES NOT BRAKE STOP PROPERLY
|
In order for the motor to 'Brake Stop' correctly the brake stop option has to be set in the USER MENU. See Page 17 Section 5.4 of the manual. | |
|
The brake volts and time settings must have values that enable the motor to brake stop correctly without undue stress to the load or motor. the ramp time must also be set so that the brake volts are applied gradually. | |
| |
||
|
If the motor \load combination is of very low inertia or the run down time is naturally short the brake stop option may not work properly or be too severe. | |
Is the power supply weak? |
If the mains power supply is poor the acceleration current may cause the voltage to 'dip' and consequently the soft starter will lose control of the ramp-down. | |
| CONTACT
YOUR SUPPLIER |
||