Link To Ralspeed Home PageLink To Ralspeed Profile PageLink To Ralspeed Products PageLink To Ralspeed Applications PageLink To Ralspeed Questions & Answers PageLink To Ralspeed Case Studies PageLink To Ralspeed Latest News PageLink To Ralspeed Keypad Demonstration PageLink To Ralspeed Downloads PageLink To Ralspeed Enquiries Page
Ralspeed Motor Control System

Questions & Answers

Q3 THE SOFT STARTER TRIPS ON FIRING FAULT

Down Arrow Start
   
Are any of the thyristor gate or cathode leads broken or loose?

Yes
Right Arrow

The gate/cathode leads are connected at the factory so unless the user has disturbed them it is very unlikely that they will be incorrect. Therefore, a FIRING FAULT will only occur if one of these is loose or broken so a simple repair should suffice. See page 2.11 of the manual.
Down Arrow No
   
Are the thyristor gate impedances as per the test certificates?

No
Right Arrow

It is possible that there is a faulty thyristor. Replace the thyristor and try a restart.
Down Arrow Yes
   
Is the motor connected correctly?

No
Right Arrow

Make sure that the motor links in the terminal box are correct. Check the voltage of the motor.
Down ArrowYes
   
Is the motor undersized for the soft starter?
Yes
Right Arrow
If the motor is not 'matched' to the soft starter it is possible that the motor impedance is too large and does not allow enough current to flow to enable the thyristor to latch.
Down ArrowNo
   
CONTACT YOUR SUPPLIER
 PHONE : 01254 582345 Site designed by eBusiness UK